• Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter
  • Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter
  • Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter
  • Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter
  • Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter
  • Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter
Favoritos

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

After-sales Service: Technical Support
Warranty: 1
Exatidão: >±1%
Aplicação principal: Natureza Gas, Corrosivo Líquido / Gás
Tamanho: DN10-50
Sensor: Embutido

Contatar Fornecedor

Fabricante / Fábrica

Tour Virtual 360 °

Membro Diamante Desde 2023

Fornecedores com licênças comerciais verificadas

Shanghai, China
Marca própria
O fornecedor possui 1 marcas próprias, verifique o Audit Report para mais informações
Entrega Rápida
O fornecedor pode entregar a mercadoria em 15 dias
Personalização a partir de designs
O fornecedor fornece serviços de personalização baseados em design
Serviços OEM
O fornecedor fornece serviços OEM para marcas populares
para ver todos os rótulos de força verificados (20)
  • Visão Geral
  • Product Description
  • Product Parameters
  • Products Size
  • Why Choose Us
  • Installation Instructions
  • Model Selection
  • Certifications
Visão Geral

Informação Básica.

N ° de Modelo.
ATMF
Aplicação
Produção Industrial
Tipo
Tipo Volume Flow Meter
Medição de mídia
Gás
Princípio de Medição
Princípios Termodinâmicos
Objeto de Medição
Pipeline Fechado
Certificação
CE, ISO
fonte de alimentação
dc24v ou ac220v
pressão de trabalho
Medium Pressure Less Than 4.0MPa
velocidade de resposta
1 seg
material do tubo
aço carbono, aço inoxidável, plástico, etc.
sinal de saída
4-20mA, Pulse, RS-485, Hart
proteção contra entrada de ar
ip65
Pacote de Transporte
Carton Box with PP Film Wooden Box
Origem
China
Código HS
9026801000
Capacidade de Produção
500 Piece/ Week

Descrição de Produto

Product Description

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

Product Parameters
Performance Technical parameter
Structural form plug-in pipe
Measuring medium All gases (except acetylene)
Diameter range Caliber DN32 or higher DN10~DN200mm
Velocity range 0.1~120Nm/s
Precision ±1~2.5%
Operating temperature Sensor:-40ºC~+120ºC        convertor:-20ºC~+45ºC
Working pressure Medium pressure≤2.5Mpa Medium pressure:4.0Mpa
Power supply DC24V or AC220V≤18W
Response speed 1s
Output signal 4-20mA (Photoelectric isolation, large load 500Ω),pulse,RS-485 (photoelectric isolation),HART agreement
Alarm 1-2 relay normally open contact,10A/220V/AC,*/30V/DC
Type of supply Separate structure, integrated structure
Pipe material Carbon steel, stainless steel
Local display Four lines of Chinese liquid crystal display
Display content Mass flow, standard volume flow, cumulative flow, standard time, cumulative running time, standard flow rate, etc
Protection degree IP65
Sensor material Stainless steel Stainless steel, carbon steel
 
Products Size

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

Why Choose Us

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

Installation Instructions

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

Installation Tips

  1. Verify the actual internal diameters and wall thickness of the pipe before installing the Insertion thermal mass flowmeter.
  2. First of all, 25 holes are opened in the pipeline, and the base is welded at the opening hole, and then the rest of the thermal mass flowmeter is loaded into the special ball valve together, and the depth to be inserted is calculated according to the actual pipe diameter and wall thickness. This step can be inserted to approximate size and hand tighten the nut.
  3. Turn the sensor connecting rod so that the marked arrow is in the same direction as the medium flow.
  4. According to the data measured in the field, convert the corresponding scale on the sensor connection rod, and lock the nut.
  5. If you are horizontally installed, the display of this instrument can be flexibly installed at 90°, 180°, 270° to meet your actual needs.

  6. Mounting base

    Do not weld in an explosive environment.
    The environment with special requirements for welding should be operated in accordance with the relevant requirements.
    The base is divided into two types according to the different installation methods: welding and clamping. When installing, the base should be located at the apex of the section direction of the pipeline, and the axis of the base through the hole is perpendicular to the axis of the pipeline. The effect diagram of the welded base has been installed (the welding position has been treated with rust prevention).

    Installing ball valves

    Secure the stainless steel valve to the base. Use a gasket on the crimped contact surface (nylon material is used when the medium temperature is below 100 ° C, copper material is used when the medium temperature is above 100 ° C).

    punching

    Before drilling holes, check the site environment carefully to ensure the safety of operations.
    Close the valve in time after drilling to avoid air leakage.
    In the case that online drilling is allowed, the opening tool of Sen Ling Instrument Co.Ltd. can be used to realize online installation without stopping production. See related instructions for the use of the tool. When stopping drilling, a variety of methods can be used to punch holes, to ensure that the axis of the hole and the base of the hole axis concentric. If the hole is opened by gas cutting, the drilling operation should be arranged before the base welding.
Model Selection

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

Certifications

Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density FlowmeterThermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter

        Q: How long is your delivery time?
        A: it depends on the quantity. Normally it's about a week to two weeks.

        Q: How to get quotation?
        A: Please tell us the pipe diameter, measuring medium, flow rate, temperature, pressure, connection type and accuracy of the product you need, we will choose the most suitable product for you.

        Q:can i design our own logo or color ?
        A:sure ! we are glad to help you.

        Q:Can I place a small order for the first time?
        A:YES. This shows your recognition of us, I believe we will have longer-term cooperation.

Envie sua pergunta diretamente para este fornecedor

*De:
*Para:
*Mensagem:

Digite entre 20 a 4000 caracteres.

Isso não é o que você está procurando? Solicitar postagem de fornecimento agora

Encontre Produtos Semelhantes por Categoria

Página Inicial do Fornecedor Produtos Massa térmica do Medidor de Fluxo Thermal Mass Helium Chlorine Gas Flow Meter Industry CO2 Thermal Gas Coriolis Mass Density Flowmeter