Task: Data Acquisition
Structure: Combination
Mathematical Model: Linear
Signal: RS-485
Function: Monitoring
Certification: RoHS, CE, FCC

Contatar Fornecedor

Fabricante / Fábrica, Empresa Comercial
Membro de Ouro Desde 2011

Fornecedores com licênças comerciais verificadas

Guangdong, China
para ver todos os rótulos de força verificados (22)
  • Visão Geral
  • Product Description
  • Product Parameters
  • Protocol and Address
  • Dimensions and wiring
  • Software and installation
  • Product Category
  • May you have interesting
  • FAQ
Visão Geral

Informação Básica.

N ° de Modelo.
A-1058
Condition
New
Customized
Customized
Material
Plastic
utilização
Computer, Data Acquisition
conteúdo da informação
dados
digite
I O Module
rede de suporte
RS-485
peso
0,3 kg
saídas digitais
12 Do Sink Transistor
Output Continuous Current
10 ~ 40VDC (200mA)
Output Operating Frequency
Transistor: 10Hz
interface de comunicação
RS - 485
taxa de transmissão de comunicação
1200 ~ 115200BPS
Protocol & Serial
Modbus RTU
tensão de funcionamento
10~30VDC/24VAC
temperatura de funcionamento
-20 to +75ºC
instalação
calha din de 35 mm
garantia
2 anos
Pacote de Transporte
Paper Box
Especificação
76.4× 118.2× 38.5 mm
Marca Registrada
ATC
Origem
China
Código HS
8543709990
Capacidade de Produção
10, 000PCS/Year

Descrição de Produto

 

Product Description

ATC's I/O module with Modbus protocol is a device that can be used to expand the input/output capabilities of a PLC or other automation system. It typically has a number of digital or analog inputs and outputs that can be used to connect to sensors, actuators, and other devices. The I/O module communicates with the PLC or other system using the Modbus protocol. They can be used in a variety of applications, including industrial automation, building automation, and process control.

RS-485 Interface:
1.Supports Modbus RTU / ASCII
2.LED Indicators I/O state
3.Isolation voltage: 5000 VDC
4.Wide operation temperature : -20 ~ +75 °C
5.Dual watchdog timer
6.Surge , EFT and ESD protection
7.Free PC software "ATC Utility
Semi-Automatic PET Bottle Blowing
8.Machine Bottle Making Machine Bottle Moulding Machine PET Bottle
9.Making Machine is suitable for producing PET plastic containers  and bottles in all shapes.
RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)

Product Parameters

Technical Specifications
Inputs
None
Outputs
12DO,Sink Transistor
Interface Type
RS-485
Support Protocols
ModBus RTU / ModBus ASCII
Data Rate
1200bps ~ 115200bps
Data Bit
8 bits
Parity
Odd, Even, None
Stop Bits
1,2 bits
Isolation Voltage
5000 VDC
Intput Rating
Logic Level 0
+1 VDC (Max)
Logic Level 1
+3.5~30 VDC
Output Rating(Max)
10 ~ 40VDC (200mA)
Output Frequency
Relay: 10Hz / Transistor:10Hz
Software
Configure Options
 Utility
OS support
Windows XP/2000/2003/Vista/7
LED Indicators
POWER/RUN  BAT/COMM
Orange/Orange/Flash
Input/Output
Red
Power Supply
10~30VDC
Power Consumption
Nearly 24VDC 0.96W
Physical Characteristics
Installation
DIN-Rail Mounting
Housing
Plastic ABS
Weight
0.3Kg
Dimensions
76.4×118.2×38.5 mm
Operating Temperature
-20 ~ 75°C
Storage Temperature
-40 ~ 85°C
Ambient Relative Humidity
5% to 95%(non-condensing) 
Standards and Certifications
RoHS, CE ,FCC
 

Protocol and Address

RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)

RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)

Dimensions and wiring

RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)

RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)
RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)
 

Software and installation

RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)
 

Product Category

RS-485 Remote I/O Module12 Do Sink Type with Modbus RTU (A-1058)

May you have interesting

RS-485 Interface Mdbus RTU/ ASCII
 
A-1057 12 DO Digital Output, Source
A-1058 12 DO Digital Output, Sink
A-1069 8 DO Digital Output, Power Relay
A-1051 16 DI Digital Input
A-1055 8DI, 8DO Sink
A-1055S 8DI, 8DO Source
A-1060 8DI, 4DO Power Relay
A-1019 4DI, 8AI (0/4~20mA A,J,K,T,E,R,S,B, Thermistor-270 ~ +1800ºC)
A-1019+ 4DI, 8AI (0/4~20mA A,J,K,T,E,R,S,B, Thermistor-270 ~ +1800ºC) RS-485 Isolated
A-1012 2DI,4AI(2*0/4~20mA,2*PT-100/1000), 2DO,2AO(0/4-20mA)
A-1012+ 2DI,4AI(2*0/4~20mA,2*PT-100/1000), 2DO,2AO(0/4-20mA) RS-485 Isolated
A-1010 IO Module, 8AI(0-10V),2AO(0-10V),4DO
A-1010+ IO Module, 8AI(0-10V),2AO(0-10V),4DO RS-485 Isolated
A-1036+ Isolated IO module, 6AO(0/4-20mA)
A-1038+
Isolated IO module, 8AO(0-10V)
 
 
Ethernet Interface Mdbus TCP
 
A-1819 Ethernet IO Module, 8AI (0/4~20mA A,J,K,T,E,R,S,B,Thermistor-270 ~ +1800ºC)
A-1812 Ethernet IO Module, 2DI 4AI(2*0/4~20mA,2*PT-100/1000) 2AO
A-1851 Ethernet IO Module, 16DI
A-1855 Ethernet IO Module, 8DI 4DO(Motor Driver 8~60V/1.75A)
A-1860 Ethernet IO Module, 8DI 4DO Power Relay (250VA/7A, 30VD/7A)
A-1869 Ethernet IO Module, 8DO Power Relay (250VA/7A, 30VD/7A)
A-1855S Ethernet IO Module,
 8DI, 4DO Source (10-40VDC/1A)
 

FAQ

1.What about the delivery time?

We will shipping this goods to customer within 1-3 work days receive the payment. For customized products, We need to decide according to the customization requirements.

2.What is your delivery terms and payment terms?

We accept EXW, FOB, DAP, etc. You can choose the one which is the most convenient or cost effective for you.

3.After service and warranty?

We provide 2 year warranty, if you have any problems in the use of products, please contact to us.

4.Are you a trader or a manufacturer?

ATC is a manufacturing and trader. We have more than 20 years ofexperience in R&D and production.

5:What is the minimum order quantity(MOQ)?

We don't have MOQ for common product. MOQ can negotiate for customized products.

6. Does your company accept customize?

Yes, welcome to OEM and label according to your requirements.

7.Can I get a lower price if l order large quantities?

Yes, Cheaper prices with bigger size orders.

8.How to make payment?

We accept T/T ,Credit card and West Union

Envie sua pergunta diretamente para este fornecedor

*De:
*Para:
*Mensagem:

Digite entre 20 a 4000 caracteres.

Isso não é o que você está procurando? Solicitar postagem de fornecimento agora