• 20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
  • 20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
  • 20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
  • 20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
  • 20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
  • 20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
Favoritos

20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner

Type: Chiller
Air Tube Material: Galvanized Sheet
Corrosion Durability: General
Operating Voltage: 380-415, 440, 460, 50/60Hz
Noise Level: Ordinary
Application Fields: Supermarket, Hospital, Pharmaceutical and Building

Contatar Fornecedor

Membro Diamante Desde 2017

Fornecedores com licênças comerciais verificadas

Fabricante / Fábrica, Empresa Comercial

Informação Básica.

Mounting
Split
Lifetime
15~20 years
Certification
ISO, CE
Condition
New
compressor
marca copeland/pansonic
peças eléctricas
marca mundialmente famosa
utilização
comercial/industrial
arrefecimento
apenas para arrefecimento ou bomba de calor
refrigerante
R22/R407c/R410A/R134A
tipo de filtro
pré, médio e hepa (opcional)
unidade interior
utilização vertical e horizontal
Pacote de Transporte
Standard Package Fit for Transportation
Especificação
Color: white
Marca Registrada
AMRTA or OEM
Origem
China
Código HS
8418612090
Capacidade de Produção
10000PCS/Year

Descrição de Produto

60Hz DX Vertical / Horizontal Air to Air Ducted Split Air Handling Unit  with Pre/Medium/HEPA Filter AHU

Cooling capacity 20kW ~ 104kW 

Product Description

11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.
Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.

Split installation, connected by means of flare/welding coupling.

Easy operation line controller:
  • Cooling/Heating/Fan/Auto
  • Timing On/Off
  • Error indication

Multi safety protection
  • High/low pressure protection
  • Time delay and antifreeze switch
  • Phase sequence relay
  • Current overload protection
  • Overheat protection
OPTIONAL
Additional electric heater on indoor unit
Additional heating coil on indoor unit


TECHNICAL DATA 
 
Mod.     20 25 32 36 42 48
Nominal cooling capacity* kW 19.5 24.8 31.2 35.6 41.3 47.4
Nominal heating capacity** kW 22.6 28.9 35.8 40.8 46.9 54.4
Connection              
Method / Flare Flare Flare Welding Welding Welding
Liquid pipe diameter ¢mm 9.52x2 12.7x2 12.7x2 15.88x1 15.88/12.7 15.88/12.7
Gas pipe diameter ¢mm 15.88x2 19.05x2 19.05x2 28x1 28/19.05 28/19.05
Power supply / 230V/3N/60Hz
OUTDOOR UNIT Compressor    
Qty/refrigerant circuit Nr. 2/2 2/2 2/2 1/1 2/2 2/2
Cooling power input* kW 7.2 9.3 11.8 12.8 15.1 17.9
Heating power input** kW 7.13 9.21 11.68 12.67 14.95 17.72
Energy adjustment % 50-100 50-100 50-100 0-100 40-60-100 33-66-100
Axial fans     
Quantity   Nr. 1 1 1 1 2 2
Airflow  m3/h 9400 9400 12500 14200 18800 18800
Sound pressure level*** dB(A) 67 67 68 70 71 71
Net weight kg 170 180 220 280 260 280
INDOOR UNIT Centrifugal fans              
Quantity Nr. 2 2 2 2 2 2
Airflow m3/h 3500 4500 5650 6450 7400 8550
ESP Pa 120 100 150 130 180 200
Sound pressure level*** dB(A) 64 64 66 66 68 68
Net weight kg 90 100 150 160 180 200
Additional electric heater**** kW 2×3 2×4 2×5 2×6 2×6 2×8
Additional heating coil**** kW 22.2 28.4 35.1 40.0 46.0 53.3
 
Mod   52 62 72 88 104
Nominal cooling capacity* kW 51.3 63.3 71.3 87.9 103.7
Nominal heating capacity** kW 58.9 72.6 81.9 100.0 115.8
Connection            
Method / Welding Welding Welding Welding Welding
Liquid pipe diameter ¢mm 15.88/12.7 15.88×2 15.88×2 15.88×2 19.05×2
Gas pipe diameter ¢mm 28/19.05 28×2 28×2 28×2 35×2
Power supply / 230V/3N/60Hz
OUTDOOR UNIT Compressor  
Qty/refrigerant circuit Nr. 2/2 2/2 2/2 2/2 2/2
Cooling power input* kW 18.4 23.1 26.6 28.1 39.3
Heating power input** kW 18.22 22.87 26.33 27.82 38.91
Energy adjustment % 30-70-100 50-100 50-100 50-100 50-100
Axial fans  
Quantity Nr. 2 2 2 2 2
Airflow m3/h 21500 26500 29880 36500 43500
Sound pressure level*** dB(A) 71 71 71 71 71
Net weight kg 330 460 460 780 800
INDOOR UNIT Centrifugal fans            
Quantity Nr. 2 2 2 2 2
Airflow m3/h 9250 11450 12900 14800 17100
ESP Pa 200 300 300 280 500
Sound pressure level*** dB(A) 68 68 69 69 70
Net weight kg 220 230 300 320 400
Additional electric heater**** kW 2×8 2×10 2×10 2×12 2×14
Additional heating coil**** kW 57.8 71.2 80.3 98.0 113.5

Performance values refer to the following conditions:
* Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.
** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7ºC / WB 6°C.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
**** Optional as request.

Unit Pictures

20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner
Some Overseas Simple Projects

20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner

Our Products Range


20kw-104kw CE Certificate Air Cooled Ducted Split Air Conditioner

Contact Information

Anne 
 
 
 
----------------------------------------------------------------------------------
JINAN AMRTA AIR CONDITIONING CO.,LTD
 
Website: jinanamrtaac.en.made-in-china.comjinanamrtaac.en.made-in-china.com

 

Envie sua pergunta diretamente para este fornecedor

*De:
*Para:
*Mensagem:

Digite entre 20 a 4000 caracteres.

Isso não é o que você está procurando? Solicitar postagem de fornecimento agora