• Advanced Active Harmonic Filter for Unbalanced Loads
  • Advanced Active Harmonic Filter for Unbalanced Loads
  • Advanced Active Harmonic Filter for Unbalanced Loads
  • Advanced Active Harmonic Filter for Unbalanced Loads
  • Advanced Active Harmonic Filter for Unbalanced Loads
  • Advanced Active Harmonic Filter for Unbalanced Loads
Favoritos

Advanced Active Harmonic Filter for Unbalanced Loads

Certificação: ISO9001, CCC, CE
Proteção: IP20
Instalação: Wall-Mount, Frame-Mount
Pacote de Transporte: Wooden Case
Especificação: can be customized
Marca Registrada: ARK

Contatar Fornecedor

Membro Diamante Desde 2022

Fornecedores com licênças comerciais verificadas

Avaliação: 5.0/5
Empresa Comercial
  • Visão Geral
  • Working Principle
  • Product Description
  • Project Case
  • Manufacturing Shop
  • Product Parameters
  • Product Packing
Visão Geral

Informação Básica.

N ° de Modelo.
AHF
Origem
China

Descrição de Produto

Working Principle

The working principle of the STD APF series active power filter is to detect the load current in real time, separate the harmonic currents one by one based on the specified harmonic current detection algorithm, and generate and control the driver IGBT output and load harmonic current according to the set filtering percentage. Compensation currents with the same amplitude and opposite phases achieve the purpose of harmonic cancellation.
Advanced Active Harmonic Filter for Unbalanced Loads

Product Description
Advanced Active Harmonic Filter for Unbalanced Loads
COMPACT HIGH PERFORMANCE
* Wall mount or cabinet mount in an ultra-compact design
* Modular design, convenient multi-module parallel, small footprint, easy maintenance
* Independent air duct and independent plate bin structure design to ensure the stable operation of equipment.
OPTIMAL HARMONIC MITIGATION
* Harmonic compensation rate>92%
* Selection of odd and even harmonics up to the 50th order
* High efficiency >97%
* Reaction time <100us Response time of <10ms
PROTECT YOUR SYSTEM FROM RESONANCE.
* The current spectrum is analysed at 1024 individual points per cycle
* System impedance at each individual harmonic is effectively 'learnt' by the AHF
* Compensation current is slowly increased with system stability closely monitored
* Should resonance be detected at any point the intelligent FFT can skip the problematic point
BALANCE YOUR LOADS AND CORRECT YOUR POWER FACTOR TOO
* In addition to harmonic mitigation the AHF can provide load current balancing
* Reactive power can be compensated for thus increasing power factor
Advanced Active Harmonic Filter for Unbalanced Loads
Project Case
Advanced Active Harmonic Filter for Unbalanced Loads
Advanced Active Harmonic Filter for Unbalanced Loads
Advanced Active Harmonic Filter for Unbalanced Loads
Manufacturing Shop
Advanced Active Harmonic Filter for Unbalanced Loads
Advanced Active Harmonic Filter for Unbalanced Loads

 

Product Parameters
TYPE
Series 220V
Series 400V
Series 500V
Series 690V
Max neutral wire current
23A
15A ,25A ,50A,
75A ,100A ,150A
100A
100A
Nominal voltage
AC220V(-20%~+20%)
 AC380V(-20%~+20%)
AC500V(-20%~+20%)
AC690V(-20%~+20%)
Rated frequency
50Hz±5%
Network
Single phase
Three-phase three-wire/three-phase four-wire
Response time
<40ms
Harmonics filtering
2th to 50th Harmonics,The number of compensation can be selected, and the range of single
compensation can be adjusted
Harmonic compensation rate
>92%
Neutral line filtering capability
/
The filtering capacity of three-phase four-wire neutral line is 3 times of that
of phase filtering
machine efficiency
>97%
Switching frequency
32kHz
16kHz
 12.8kHz
 12 .8kHz
Feature selection
Deal with harmonics/Deal with harmonics and reactive power
Deal with harmonics/Deal with harmonics and reactive power/ Deal with harmonics and three-phase unbalance /Three options
Numbers in parallel
No limitation. A single centralized monitoring module can be equipped with up to 8 power modules
Communication methods
Two-channel RS485 communication interface (support GPRS/WIFI wireless communication)
Altitude without derating
<2000m
Temperature
-20~+50°C
Humidity
<90% RH,The average monthly minimum temperature is 25ºC without condensation on the surface
Pollution level
Below level 3
Protection function
Overload protection, hardware over-current protection, over-voltage protection, power failure
protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc
Noise
<50dB
 <60dB
<65dB
Installation
Rack/wall hanging
Rack
Into the way of line
Back entry (rack type), top entry (wall-mounted)
Top entry
Protection grade
IP20
Product Packing
Advanced Active Harmonic Filter for Unbalanced Loads
Advanced Active Harmonic Filter for Unbalanced Loads
Advanced Active Harmonic Filter for Unbalanced Loads

 

Envie sua pergunta diretamente para este fornecedor

*De:
*Para:
*Mensagem:

Digite entre 20 a 4000 caracteres.

Isso não é o que você está procurando? Solicitar postagem de fornecimento agora

Também Pode Gostar

Contatar Fornecedor

Membro Diamante Desde 2022

Fornecedores com licênças comerciais verificadas

Avaliação: 5.0/5
Empresa Comercial
Número de Empregados
9
Ano de Fundação
2018-03-01